MicroRhizons

pore water samplers for the RhizonBox



overview

MicroRhizons are mainly used in RhizonBox and agar tests.

They consist of two parts: a porous part of 8 mm with an outer diameter of 1 mm, and PEEK tubing with a connector fit to a syringe.

The yield of MicroRhizons is up to 2 ml. As the tubing of MicroRhizons consists of PEEK and a special glue, it is possible to steam-sterilize them.

RhizonBox

RhizoboxRhizonBoxes for a direct sampling of soil moisture in the rhizosphere during growth experiments or root research.

In the front plate, there are 2183 holes with a lateral distance of 5 mm, which allow direct sampling near the roots with MicroRhizons.

The dimensions of the RhizonBox are: height 33 cm, width 22 cm, depth 4 cm.

RhizonBox User Guide

rhizon models

19.21.81 10 x MicroRhizon with an exposed porous part of 0.8 mm with an outer diameter of 1 mm, glued on 12 cm PEEK tubing 0.6*0.4 mm. The PEEK tubing has a 0.1 mm hole about 3 mm from top for sampling
19.21.82 10 x MicroRhizon with an exposed porous part of 0.8 mm with an outer diameter of 1 mm, glued on 12 cm PEEK tubing 0.6*0.4 mm. The PEEK tubing has a 0.1 mm hole about 3 mm from top for sampling. This part is supplied with loose 5 cm PEEK tubing 1.6 mm OD, which is used as guide tubing to push your MicroRhizon into agar or other media
accessories for MicroRhizons
19.21.84 5 cm PEEK tubing, 1.6 mm OD, guide tubing to push your MicroRhizon into agar or other media
19.21.85 30 cm PEEK extension tubing 0.6*0.4 mm, 30 cm, including silicon connectors
19.21.88 10 x Syringe PP with Luer tip, 5 ml
19.31.80 1 x RhizonBox, for direct inserting of MicroRhizons, 33 x 22 cm

specifications

basic characteristics
  • Microfiltration membrane with a nominal pore size of 0.12 – 0.18 µm
  • Hydrophilic membrane composed of a blend of polyvinylpyrrolidine and polyethersulfone
  • Structure asymmetric/microporous
  • High performance and a very good anti-fouling behaviour
  • Suitable for filtatrion outside-in and inside-out
performance data
pH-range 2 – 12
Temperature 1 – 90ºC
Pressure -300 – +300 kPa
solvent resistance
 Solvent  Resistance
 Acids

++

 Bases

++

 Organic esters, ketones, ethers

 Aliphatic alcohols

+

 Aliphatic hydrocarbons

+

 Halogenated hydrocarbons

 Aromatic hydrocarbons

 Polar organic solvents

 Oils

++

storage

Store in a dry, normally ventilated place, away from sources of heat, ignition and direct sunlight. Store between 0 and 50 ºC (32 – 122F). The membrane modules should not be subjected to any freezing temperatures.

related products